PTC thermistor for telecom equipment Exchange and main distribution frame (MDF)
|
|||||||||||||
|
PTC thermistor for telecom equipment Exchange and main distribution frame (MDF)
|
|||||||||||||
General
Advanced developments in telephony equipment in recent years have
radically altered the protection requirements for both exchange and
subscriber equipment. PTC thermistor protect telephone line against
overcurrent, which mainly caused by the following examples:
Surges due to lighting strikes on or near to the line plant.
Short-term induction of alternating voltage from adjacent power
lines or railway systems, usually when these lines or systems occur
fault.
Direct contact between telephone lines and power lines.
Main parameters
Rated zero power resistance
Ambient temperature: 25±2℃,within the allowable tolerance.
Non-trip characteristic
Ambient temperature: 40±2℃in still air for 30 minutes, power
voltage 60VDC, maximum non-trip current ON for 60 minutes.
(R-Rn)/Rn≤50%
Overcurrent trip characteristic
Relation between trip current to trip time of PTC thermistor.
Over voltage withstanding
Power voltage: 230 Vrms /250 Vrms, maximum current ON for 30
minutes. 4 hours after restoring in room temperature, retest zero
power resistance, R/Rn≤20%.
Over current withstanding
Power voltage 220Vrms, maximum current 60S ON/600S OFF, cycles:
20, 4 hours after restoring in room temperature, retest zero power
resistance, R/Rn≤20%.
Surge current withstanding
Short circuit wave: 10/1000s, minimum opening circuit voltage:
1.0KV, peak current:25A, interval time: 3 minutes, cycles: 30,4
hours after restoring in room temperature, retest zero power
resistance, R/Rn≤20%.
Induction voltage withstanding (Only for maximum voltage over 600V)
Power voltage: 600 Vrms /650Vrms,initial current 1.1A, 2S ON/600S
OFF, cycles: 10, 4 hours after restoring in room temperature,
retest zero power resistance, R/Rn≤20%.
Fail model
Ⅰ. Power voltage: 250Vrmsinitial current: 10A.
. Power voltage: 600Vrms initial current: 15A
. Power voltage: 650Vrmsinitial current: 10A
Energized time 30 minutes, high resistance state or open circuit is
allowable. Low resistance or firing is not allowed.
Restore time
The time necessary for PTC thermistor returning to twice Rn. Lower
than 60 seconds is required.
Operating principle
A PTC thermistor is connected in series with each telephone line,
usually as secondary protection. Please refer to fig. 1, however,
even with primary line protection(usually a gas discharge tube),
the PTC thermistor must fulfill severe requirements. Surge pulses
up to 2KV can occur and in order to withstand short term power
induction, the PTC thermistor must withstand high voltages. If the
line has primary protection, a 200V ~300V PTC thermistor is
adequate. Without primary protection, 600V PTC device is necessary.
Ampron manufactures a series of PTC thermistor fulfilling both
requirements.